76-80 81-85 86-90 91-95 96-100
100
Disconnect the power from the circuit being tested.
When using an ohmmeter to take a resistance reading, what preliminary precaution should you take?
100
number of bits that can represent the total number of bits in the test pattern.
The size of a test pattern segment transmitted from a bit error rate test (BERT) is determined by the
100
auxiliary potential electrode and the earth test ground electrode.
Voltage potential is measured in the fall of potential ground testing method between the
100
Trace route.
What active test is selected to see the path that the packets are traveling and the time it takes the packets to compete the trip?
100
Decibels
Which of the following is not a type of power level displayed by a power meter?
a. dBm. b. Watts. c. Decibels. d. Milliwatts.
200
Auto.
Which mode of triggering an oscilloscope causes a trace to be drawn on the screen at all times, whether there is an input signal or not?
200
Bipolar violation.
What type of error is the result of two successive logic one pulses of the same polarity that violates alternate mark inversion coding rules?
200
5 ohms or less.
The Institute of Electrical and Electronics Engineers (IEEE) has recommended a ground resistance value of
200
align telemetry receivers.
A radio frequency generator is used to
200
frequency and power to be measured.
Plug-in elements of the wattmeter are selected based on the
300
Passive 1:1.
Which oscilloscope probe is essentially just a shielded piece of wire?
300
Bit slip.
What type of error is the result of a bit not positioned where it should be?
300
Buffer
What component of a protocol analyzer stores all frames based on the user configuration inputs?
300
Frequency counters, universal counters, microwave counters, and reciprocal counters.
Which are the correct four classes of electronic counters?
300
Communication service monitor.
What test equipment combines the operations of many test instruments into a single compact unit?
400
Microprocessors
What area of a digital storage oscilloscope takes digitized samples and performs numerous manipulations on the data including measuring rise and fall times, periods, time intervals, and performing math computations?
400
Disconnect the earth electrode under test from its connection to the site.
What is the first step in testing ground?
400
Central processing unit.
What component on a protocol analyzer process the frames based on the selected test and user configuration inputs?
400
10 dB.
The 10:1 power ratio represented by 1 bel can also be represented by how many decibels (dB)?
400
Analog multimeter.
What function is not part of the communication service monitor?
a. Radio frequency generator. b. Analog multimeter. c. Oscilloscope. d. Receiver.
500
Linear.
In real-time sampling, what type of interpolation is used when measuring pulse waves?
500
auxiliary current probe.
A known current is generated by the earth ground tester between the earth ground electrode and the
500
Packet internetwork groper (PING).
What active test is selected to determine if a network node is connected or responding?
500
3 dB.
When transmitter decibel (dB) power is doubled, it has increased by
500
Function generator
What operational capability of the communication service monitor produce sine, square and triangle waveforms?






Z3D153 VOL 1 URE 76-100

Press F11 for full screen mode



Limited time offer: Membership 25% off


Clone | Edit | Download / Play Offline