General Information Gas Measurement Crude Measurement Accuracy
100
What are MFD's? Measurement Flow Diagrams
Measurement points showing origin of production to disposition shall be documented using this process.
100
What is tolerance and frequencies
XTO witnessing activities of
those third-party meters are based these.
100
What is LACT and Tank Gauging
Crude oil custody shall be measured by these two methods
100
What is verification / certification papers
The papers for the equipment shall be kept for the current period and one previous period for tracking purposes
200
What is a Measurement Point. (MPT)?
A specific device or a combination of devices used to account for and to measure the quantity and quality of hydrocarbon or other fluids is defined as.
200
what is Verification / Calibration
This should be reviewed by the local measurement team and preformed only when measurements are outside established tolerances.
200
What is a Pre-Sale
This process should be used where witnessing cannot be performed.
200
What is Custody Transfer
Accuracy requirements for Instruments used in this process may need to be more accurate than those for Process Measurements
300
What is an Exception?
This process must be applied when departing from defined measurement standards.
300
What are Flange Fitting Orifice Plates
This should be inspected on an annual basis if a field/plant shutdown would not be required.
300
What is a witness
This person must ensure that the shakeout, gravity test, and temperature readings are determined as per API procedures
300
What is centrifuge
This method is the only way to determine both sediment and water in one test.
400
What is XTO - Specific Measurement Requirements - (6MAP)?
ExxonMobil (EMPC) manual Part 6 refers to this as.
400
What are Ultrasonic Meters
These are calibrated at a laboratory flow loop facility traceable to a National Metrology Institute (NMI) or proved/verified using a master meter in series.
400
What are Float and Hydrostatic ATG's
These cannot be used for custody transfer without an approved exception
400
What are RTD's
These devices should have the ability to simulate temperatures to within a resolution of 0.2 °F.
500
What is CIMS?
This system is structured to promote ongoing integrity of business controls.
500
what are GAS CHROMATOGRAPHS
These should be located as close to the sample point as possible with a proper shelter should be maintained
500
Reference Point or Tank Gauge Reference Point
This point is to be agreed on by the Operations Technician and the Purchaser.
500
What are Portable Deadweight testers and pump-up hydraulic or pneumatic pressure testers
The two devices are most frequently used as a pressure source






XTO Measurement