100
Yes
Is an elevator a confined space?
100
Near water
The most dangerous place to use electrical equipment is?
100
3
Top rail height of a guardrail system is 42 inches plus or minus ______ inches.
100
Falls, Electrical, Struck-By, Caught in Between
Name the Focus Four in construction?
100
Employees, Material, or both
Scaffolding is a elevated platform meant to support which two things?
200
As soon as any part of the body crosses the plane of the confined space opening
When has an employee entered a confined space?
200
10 feet
What is the safe distance to work from overhead power lines?
200
200 pounds
How many pounds of downward/outward force must a top rail of a guardrail system support?
200
2 inches
Holes means a gap or void of how many inches in its least dimension?
200
4 times (6 times for suspension scaffolding)
Scaffolds must be able to support ____ times the maximum intended load?
300
Oxygen content, flammable atmosphere, and toxic atmosphere
What are the three main atmospheric hazards of a confined space?
300
5 foot candles
How many foot candles of light are required in work areas?
300
900 pounds
How many pounds of force must fall arrest equipment limit on the body?
300
Falls
What is the leading cause of fatalities in construction of the Focus Four?
300
4 to 1
Supported scaffolding must be secured to the structure at what height to base ratio?
400
Large enough to enter, limited means of entry and exit, and not designed for continuous occupancy
What are the three characteristics of a confined space?
400
A fast-acting circuit breaker that shuts off electric power during a break in grounding (ground-fault) so current does not go through the user
What is the purpose of a ground-fault circuit interruptor?
400
500 pounds
How many pounds of tensile strength must warning line ropes, wires, or chains have?
400
Employees
Who has the most impact on improving safety on a construction site?
400
18
Accessible plank on a platform greater than 10 feet in length shall not cantilever over its support more than ______ inches?
500
Potentially hazardous atmosphere, an engulfment hazard , an entrapment hazard, OR any other recognized serious safety and health hazard
What are two of the four permit-required confined space characteristics?
500
3 feet
How many feet of clearance are required around electrical panels?
500
18 inches
An opening means a gap or void 30-inches or more high and ____ inches wide, in a wall or partition, through which employees can fall to a lower level.
500
Elimination, physically remove the hazard
Hierachy of Controls, what is the best way to control hazards in construction?
500
22 inches
When erecting and dismantiling welded frame scaffolding, what is the allowable distance between horizontal members to climb vertically?