electrics / oxygen | cooling | hydaulics | EGEN | Misc |
---|---|---|---|---|
What is p/cp bfd, cxp transponder, l/r smartprobes, bailout bell, egi 1/2, emirs guillotine, fuel manifold drain valve, fire extinguisher l/r
items on flt batt
|
What is polyalphaolefin (pao)
lcs liquid
|
What is 2x 3000psi
number an pressure of system
|
What is both gen switches off and emer gcuoff
how to isolate all busses
|
What is ro cdu
vcs alert page
|
What is 24 vdc, 15ah, charger is 50ah, 28 vdc, 2 hr life, maximize by turning off pilot cdu and limiting emer ics use
battery sys description
|
What is med/high (<87), low (<105), on/stby/ ground check (<120)
lcs limits
|
What is 11, 1/ 2/ 12
filters/ nonbypass
|
What is loss of power to warn bus 2 or egen switch to manual
egen turn on
|
What is radar transmitter, cec transceiver, cec power converter, power on via lcs on and rdr on or just cec on
lcs systems and operation
|
What is 3 phase, 400 hz, continuous 170 kva max 255 kva for 3 hr, online at 96.7 until 93.7
engine driven generator characteristics
|
What is high flow (40-54, wow, oat <90, rdr in stby/op), low flow (16-27)
rpcs modes and requirements
|
What is 5.8 total, 1.3 res, 1 low, 7.5 gpm
flight system quantities
|
What is ess ac bus 1/2, ess dc bus 1/2, 26vac 1/2, warn bus 1
egen powers these
|
What is keep (wing/tail de-ice, hydro reservoir, inflatable seals, rpcs, engine anti-ice/cooling) and lose (nose anti-ice, air conditioning and pressure, side window defog)
FBAV closed
|
What is supply must be set to off when not in use otherwise free flowing obogs can cause contamination in the concentrator, overstress of the system, and create unusable air during an emergency
oxygen regulator warning
|
What is auto 634, cool 204/48-69, heat 10-30/65-90, normal pressure 13-20
vcs timeout/temps
|
What is 14 total, 3.3 res, 2.1 low, 25 gpm
combined sys quantities
|
What is bfds, afmc 1, nfs 2, dcp, mmr, acls, tacan, egi 1/2, smartprobes, p/c/aco cdu, p/s pfd
nav equipment on egen
|
What is provide cool, dry, conditioned air to : high pressure rf transmission lines, pam rack, rotary coupler assembly, ar probe purge
rpcs action / systems
|
What is 45-55, 38 low
obogs pressures
|
What is interlocked (radar, iff, cec, esm), cooled (utfa fm/L11/satcom, hf, mids-on, mcd, mpdb, fcns), aironly (utfa am)
items cooled by vcs
|
What is wheel brakes, wing flaps, wing folds, wipers, rotodome rotation, emer gen, nose wheel steering, tail skid, arresting hook, landing gear
items on combined system
|
What is transponder, radios 1/2, ics, guard receiver, rcu 1/2, radio interface unit
comm equipment on egen
|
What is capacity of 12400lbs, dump from full to 20% per tank in 9.5 min, 1240lb per tank
fuel system and dumping
|