CH. 6 CH. 7 CH. 7 CH. 7 CH. 7
100
What is KRYPTON
GAS LASER, RED LIGHT MOST FREQUENTLY USED
100
What is COMMENSALISM
ONE ORGANISM BENEFITS AND THE OTHER IS NEITHER HARMED NOR BENEFITTED
600
What is DISINFECTION
DESTRUCTION OF PATHOGENIC MICROORGANISMS OR THEIR TOXINS OR VECTORS BY DIRECT EXPOSURE TO CHEMICAL OR PHYSICAL AGENTS
What is ETO, STEAM
PLASTIC COMBINATION POUCH PACKAGES ARE USED IN WHICH STERILIZERS
What is 270, 3 MINUTES
TIME AND TEMPERATURE REQUIRED FOR AN INSTRUMENT SET, UNWRAPPED, WITH NO LUMENS IN GRAVITY DISPLACEMENT
200
What is EXCIMER
ULTRAVIOLET LASER BEAM, USES GASES AND HALOGENS
200
What is DYNAMIC AIR REMOVAL STEAM STERILIZER, GRAVITY DISPLACEMENT STERILIZER
WHICH STERILIZER(S) REQUIRES A DRYING PHASE
700
What is LOW LEVEL DISINFECTION
KILLS SOME FUNGI AND VIRUSES AND MOST BACTERIA BUT IS NOT EFFECTIVE AGAINST SPORES AND M. TUBERCULOSIS
What is TYVEK PLASTIC COMBINATION
WHAT TYPE OF POUCH COMBINATION IS USED FOR ETO AND STERRAD STERILIZATION
What is 15 MIN
TIME REQUIRED FOR A WRAPPED INSTRUMENT SET IN A GRAVITY DISPLACEMENT AT 270 DEGREES
300
What is ARGON
PRODUCES VISIBLE BLUE OR GREEN LIGHT AND THE PRIMARY COMPONENT IS THE PLASMA TUBE THAT CONTAINS THE GAS
300
What is MECHANICAL, CHEMICAL, BIOLOGICAL, ADMINISTRATIVE (DOCUMENTATION)
WHAT ARE THE FOUR METHODS OF MONITORING THE STERILIZATION PROCESS
800
What is CHELATION
PROCESS OF BINDING MINERALS SUCH AS IRON AND MAGNESIUM IN THE SOLUTION
What is 7 LBS
THE WEIGHT OF WRAPPED BASIN SETS SHOULD NOT EXCEED
What is 4 MIN
TIME FOR A WRAPPED INSTRUMENT SET IN A DYNAMIC AIR REMOVAL AT 270
400
What is ND:YAG
INVISIBLE WAVELENGTH, CAN BE DELIVERED BY CONTACT OR NON CONTACT FIBER DELIVERY SYSTEM
400
What is GRAVITY DISPLACEMENT STERILIZER
THIS RELIES OF GRAVITY TO PASSIVELY REMOVE AIR FROM THE STERILIZATION CHAMBER
900
What is STERILE WATER BECAUSE SALINE WILL PIT INSTRUMENTS, ENZYMATIC SOLUTIONS, DETERGENT SOLUTIONS
WHAT DO WE USE TO DECONTAMINATE INSTRUMENTS AND WHY
What is 12X12X20, 12 LBS
WHEN USING MUSLIN WRAPS THE RECOMMENDED MAXIMUM SIZE IS AND IT MUST NOT WEIGHT MORE THAN ___ POUNDS
What is GAS, USED FOR INSTRUMENTS THAT ARE HEAT/MOISTURE SENSITIVE
WHAT TYPE OF STERILIZATION IS ETHYLENE OXIDE AND WHY IS IT USED
500
What is ND:YAG
LASER IN GASTROINTESTINAL ENDOSCOPY
500
What is DYNAMIC AIR REMOVAL TEST, BOWIE DICK, DYNAMIC AIR REMOVAL
A DART TEST IS A TYPE OF ______ TEST FOR THE ____ STERILIZER AND WHAT DOES IT STAND FOR
What is ON THEIR EDGE WHEN PLACED IN A STERILIZER AND POSITIONED PAPER SIDE TO PAPER SIDE AND PLASTIC SIDE TO PLASTIC SIDE TO ENSURE AIR REMOVE, STERILANT PENETRATION, AND DRYING
HOW ARE PEEL PACKS PLACED IN A STERILIZER
What is STEAM STERILIZATION
WHAT IS THE RECOMMENDED STERILIZATION METHOD FOR ITEMS THAT ARE NOT HEAT, MOISTURE, OR TEMPERATURE SENSITIVE
What is ETO CAN BIND WITH WATER CREATING ETHYLENE GLYCOL (ANTIFREEZE)
WHAT CAN HAPPEN IF THERE IS WATER PRESENT IN TUBING OR LUMENS IN A ETHYLENE OXIDE STERILIZER