PSCG and It's Functions Welcome to the ECS How Much Do You Know? Control and Display Mode Control Specifics
100
What is +27 VDC
This Voltage is used by the WCG Computer.
100
What is 60F or below.
This is the temperature in which the Radome Heater is activated.
100
What is 5 - 1,2,3,13&14
The Number of UNITS included in a 1B B/L 0 Mount Configuration.
100
What is AIR READY
The lowest mode in which you may command SURFACE Mode from.
100
What is BATTERY OFF
The Lowest Operating Mode of CIWS.
200
What is 29 (1A) or 32 (1B)
This is the number of Circuit Breakers on the 2A6A1 Front Panel Assembly.
200
What are Flow Switches/Flow Sensors
There are Four (4) of THESE in the Coolant Loop.
200
What are System Control Keyswitch to OPERATE and MOUNT WARNING.
You need to do these two (2) things prior to pressing AIR READY, according to the proceedure.
200
What is Passive Ranging
The default Ranging method in Surface mode.
200
What is 3
The number of phases that make up Air Ready.
300
What are 115v (VRU) and 26v (RSI)
These two voltages are converted into 400 Hz in the PSCG.
300
What is 3 (+/-2) psi
The Waveguide is pressurized to this psi.
300
What is the 2A12(A1) Front Panel
This Drawer/Door houses Two TIM CCAs and Two Voltage Conditioner CCAs.
300
What are +12vdc and +5vdc
THESE Voltages are used exclusively for the VME Bus and CCAs.
300
What is STANDBY
Lowest Mode of Operation that you can "Hand over" control to the RCP.
400
What is 10 seconds (Approx.)
The length of time needed for the Power Quality Monitor (PQM) to complete One full Override Cycle.
400
What is 30 seconds
The normal cycle time for the WADS Tower to change between the Upper and Lower Dryer Assemblies.
400
What is PRE ARM/ARM/SAFE button (Switch)
If all conditions are met, pressing THIS button will give you a GUN STATUS GO indication.
400
What is the PSP CCA
The "WCG for the EO Subsystem".
400
What is STANDBY (Just)
The System wil default into THIS Mode if the Mount Safety switch is Set to SAFE.
500
What are +/- 28.5 vdc and +/- 8.5vdc
These Voltages are monitored by 2A12A1A2 producing the ELX OK - H signal, turning the ELX POWER Switch to green.
500
What is the ELX Temperature (sensor)
This ECS Sensor (2A14S7) is misleading because it is located behind the 2A9 drawer.
500
What is CSOSS
Tables 3-19 and 3-20 are used to make up THIS proceedural Document.
500
What is TARGET DATA - HEIGHT Readout
The Standby countdown is displayed in THIS Readout on the LCP.
500
What are STANDBY and STANDBY-ELX (AIR READY)
The EM and ELX Power Supplies are activated in THESE Modes, Respectively.






CIWS Review