Fire Alarm Devices Fire Alarm Systems Commercial Services Emergency / Standby Systems Potpourri
100
manual pull station (key-operated, double-action, glass-break), spot detector, beam detector, UV flame detector, infrared flame detector, fixed heat, rate-of-rise heat, duct detector, line detector, air-sampling detector, cloud chamber smoke, photoelectric, ionization, sprinkler system (water flow detector)
Provide 3 examples of an initiating device, be specific
100
End of Line resistor
What small device is required at the end of a Class B/conventional circuit?
100
Service lateral
A utility supply of underground service entrance conductors is called a ________________
100
The NEC Article addressing Places of Assembly
What is Article 518?
100
NICET (National Institute for Certification in Engineering Technologies)
What organization establishes standardized testing for designers and installers of fire alarm systems?
200
decibels (dBA) & candelas (cd)
Horn/strobes are rated (or measured) in _________ and ____________.
200
normal, trouble, alarm
And IDC can monitor for three states/conditions? What are they?
200
5 dials, kilo-watt hours
How many dials does an analog meter have? What does it measure?
200
Legally Required Standby Systems
What system is installed to protect loads such as communications, ventilation, industrial processes or lighting that, when stopped, could create hazards or hamper rescue or fire fighting operations?
200
Electromagnetic interference
If you cover a sensor during a trouble-shooting procedure and it still malfunctions, the problem could be caused by ______________________.
300
CFM (cubic feet per minute), BTU (British Thermal Units), tonnage
What are the three methods for sizing for HVAC systems? How are they sized?
300
24 hours
Standby or Emergency Power for a fire alarm panel is required to be a minimum of ____________?
300
Main disconnect is installed ahead of, or on line side of the meter - allows for service of meter in de-energized state
What is cold sequence metering?
300
Nickel-Cadmium
What type of battery is better suited for extreme temperature conditions?
300
Main Service Disconnect
To provide flexibility in a commercial building before the number of tenants is knows, the parallel service-entrance conductors should terminate in a _______________________________.
400
42" and 54"
According to ADA standards pull stations can be mounted at a minimum of __________ inches and a maximum of ___________ inches.
400
.7 x listed spacing
What is the minimum spacing criterion for a smoke and/or heat detector in front of a FACP?
400
Special Conditions (fire pumps, emergency/standby power, power reliability) Special Occupancies, Capacity Requirements, Different Characteristics
According to NEC code, list at least 4 scenarios under which a building can have more than one service.
400
8 receptacles minimum, 517.18 B
Patient care areas shall be provided with how many receptacles?
400
Destroy the positive plate
Overcharging a lead-acid battery will ________________________.
500
90 seconds
A sprinkler flow alarm must be initiated within ________ of flow of water equal to or greater than flow from a sprinkler head?
500
Digital Alarm Communicator Transmitter (DACT)
What is the digital device that sends fire alarm information over a public switched telephone network called?
500
porcelain insulator attachments
What provides a separation between the service drop conductors and other metal components?
500
re-chargeable battery, battery charger and 1 or more lamps
List the 3 components required for an emergency lighting unit?
500
85 dBA at 10ft
All residential alarm-sounding devices must have a minimum rating of ___________?