					 Name the 3 smart features of the Amia | 
					  the primary program is the program that you will use most often.  it is loaded as the default program					 
					 Primary Program | 
					  30 days					 
					 After how many days of not logging into Sharesource will you need your password reset? | 
					  The drain exceeds the MPV by at least 15%					 
					 Excessive Drain Deviation means | 
					  10					 How many characters are available for Program Name | 
| 
					  Automatically adjust the dwell times up or down to complete the treatment in the prescribed therapy time					 
					 What is Smart Dwell | 
					  a therapy that requires the clinician to program the therapy time, night therapy volume and fill volume					 
					 Time-Bases Method | 
					  4					 
					 How many treatments can you program into Sharesource | 
					  PD 4 low Calcium 1.25 mmol/L PD 101 high Calcium 1.75 mmol/L 
					 What is the Difference between PD 101 and PD 4 | 
					  Cord Modem 
					 When a patient has to swap out their cycler what do they need to keep? | 
| 
					  Smart therapy is a tidal therapy that uses most of the available solution.  Does this by adding 1 or 2 extra cycles to the treatment					 
					 What is Smart Therapy | 
					  a therapy that requires the clinician to program the cycle fill volume, dwell time and number of cycles					 
					 Cycle based Method | 
					  No					 
					 Can you log into Sharesource at any time and see how a patients treatment is going> | 
					  Your UF is significantly more or less than expected for the night portion of therapy					 
					 Expected UF Deviation means | 
					  Yes					 
					 Is a new patient consent required when ever a patient has to swap out their cycler? | 
| 
					  Smart drain is a treatment option that allows you to continue treatment when experiencing drain problems during the night portion of therapy .					 
					 What is Smart Drain | 
					  When the patient connects to the Amia cycler during the day to complete a exchange.					 
					 Day Cycles | 
					  Not true only issues you have chosen as a alert will be flagged					 
					 Any issues during treatment will be flagged on the Sharesource dashboard | 
					  You drained significantly more or less than expected in the initial drain. (min initial drain setting-the actual drain)is not withing =/- 50% of night fill volume per cycler 
					 Initial Drain Deviation means | 
					  Amia Care is a Baxter service which provides proactive maintenance to the Amia system to lessen the likelihood that a patient will experience a therapy interruption. Preventive maintenance is performed while the equipment is still working to keep it running smoothly					 
					 What is Amia Care?? | 
| 
					  Smart Drain Limit Volume is the MPV allowed to remain tin the peritoneal cavity prior to moving on to the next fill phase					 
					 What is the Smart Drain Limit Volume | 
					  the amount of fluid the system has calculated to be in the peritoneal cavity during you APD night therapy.					 
					 Estimated Peritoneal Volume | 
					  True					 
					 Baxter needs that patients Date of birth for the patient to be activated in Sharesource | 
					  Lost total therapy volume is greater than 5%					 
					 Lost dwell time Deviation means | 
					  Date and Time					 
					 What do you or your patient need to check whenever you are using a new Amia cycler |